Owon XSA805TG 9kHz to 500MHz Spectrum Analyser

Owon XSA805TG 9kHz to 500MHz Spectrum Analyser

$2,063.41

$2,063.41 (ex GST)

$2,269.75 (inc GST)

On Backorder

Product Code: XSA805-TG


Brand: Owon

Owon XSA805TG 9kHz to 500MHz Spectrum Analyser� Frequency range 9kHz - 1.5GHz� 160 dBm Displayed Average Noise Level (DANL)� Phase noise -80 dBc/Hz &, ;1GHz and offset at 10 kHz� Total amplitude accuracy <0.7 dB� 1 Hz minimum resolution bandwidth (RBW)� EMI pre-compliance test kit, optional EMC test software� Optional tracking generator (standard tracking generator� hardware, can be remotely upgraded according to needs)� Waterfall plot graphic, modulation signal quality analysis,� audio demodulation, ect. multiple general and extended� test functions.� Standard Pass/Fail on-site test and alert function� Adopt all-digital intermediate frequency technology� Multiple interfaces: USB Host, USB Device, LAN,� earphone interface, HDMI� 9-inch LCD, high resolution 1280�800 pixels Specifications Frequency Frequency Range XSA805(TG) 9 kHz to 500 MHz XSA810(TG) 9 kHz to 1 GHz XSA815(TG) 9 kHz to 1.5 GHz Frequency Resolution 1 Hz Reference frequency aging rate < 1 ppm/year Frequency Span Span Range 0 Hz, 100 Hz to max frequency of instrument Span Uncertainty ± span / (sweep points-1) SSB Phase Noise(20? to 30?, fc = 500 MHz) Carrier Offset 10 kHz < -80 dBc/Hz 100 kHz < -100 dBc/Hz 1 MHz < -115 dBc/Hz Bandwidth Resolution Bandwidth(-3 dB) 1 Hz to 1 MHz, in 1-3-5-10 sequence Resolution Bandwidth (-6 dB) (EMI) 200 Hz, 9 kHz, 120 kHz, 1 MHz RBW Accuracy < 5% typical Resolution Filter Shape Factor (60 dB : 3 dB) < 5 typical VideoBandwidth (-3 dB) 10 Hz to 1 MHz, in 1-3-5-10 sequence Amplitude and level Amplitude measurement range DANL to +10 dBm, 100 kHz to 10 MHz, Preamp OffDANL to +20 dBm, fc = 10 MHz, Preamp Off Reference Level -80 dBm to +30 dBm, 0.01 dB by step Preamp 20 dB, nominal, 100 kHz to 1.5 GHz Input Attenuator XSA805(TG)XSA810(TG)XSA815(TG) 0 to 40 dB, 1 dB by step Display Average Noise Level (Input attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average = 50, 20? to 30?, input impedance = 50 &, ;) Preamp Off 9 kHz to 1 MHz -95 dBm (Typical), <-88 dBm 1 MHz to 500 MHz -140 dBm (Typical), <-130dBm XSA810(TG) 500 MHz to 1 GHz XSA815(TG) 500 MHz to 1.5 GHz -138 dBm (Typical), <-128 dBm Preamp On 100 kHz to 1 MHz -135 dBm (Typical), <-128 dBm 1 MHz to 500 MHz -160 dBm (Typical), <-150 dBm XSA810(TG) 500 MHz to 1 GHz XSA815(TG) 500 MHz to 1.5 GHz -158 dBm (Typical), <-148 dBm Level Display Trace detectors positive-peak, negative-peak, normal, sample, RMS, voltage average, quasi-peak Trace functions clear write, max hold, min hold, average, view, blank, trace math Units of level axis dBm, dBµW, dBpW, dBmV, dBµV, W, V Frequency response(fc = 100 kHz, 20? to 30?,30% to 70% relative humidity, input attenuation=10 dB, reference frequency= 50 MHz) Preamp Off <0.7 dB Preamp On <1.0 dB Difference and Accuracy Uncertainty fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB, input signal level = -10 dBm, 20? to 30? < 0.4 dB Level Measurement Uncertainty Level measurement uncertainty 95% confidence level, S/N > 20 dB, RBW = VBW = 1 kHz, preamplifier off, attenuation = 10 dB, -50 dBm < input level = 0 dBm, fc > 10 MHz, 20? to 30? < 0.7 dB Tracking Generator (optional) Frequency Range  XSA805(TG) 100 kHz to 500 MHz XSA810(TG) 100 kHz to 1 GHz XSA815(TG) 100 kHz to 1.5 GHz Output powerlevel range -40 dBm to 0 dBm Output level resolution 1 dB Output flatness Relative to 50 MHz ± 3 dB Tracking generator spurious Harmonic spurious -30 dBc (Tracking generator output power -10 dBm) Non-harmonic spurious -40 dBc (Tracking generator output power -10 dBm) Tracking generator to input terminal isolation -60 dB (Tracking generator output power 0 dBm) Interface USB Host, USB Device, LAN, earphone interface, HDMI Display 9-inch TFT LCD, 1280 x 800 pixels Appearance Dimensions 375 mm (W) � 185 mm (H) � 12